(AI KB) Bullhorn: RM4014 Not Communicating- Troubleshooting Flowchart

If an RM4014 does not acknowledge commands or call in as scheduled, please follow the steps below.

 

Steps

  1. Check the battery. Measure at the battery leads. It should read above 12.6 V. If it does not, replace it with a battery charged above 12.6 V, then check again.
  2. Check the DC power input. It should read 12 to 14 V DC. If it does not, check the power supply and its power source, then check again.
  3. Check the satellite terminal. It needs the right orientation and a clear line of sight to the sky. Fix anything that blocks it, then check again.
  4. Check the satellite cable. Make sure both ends are tight and the cable is not damaged. Replace a damaged cable, then check again.
  5. If the unit still does not call in or acknowledge commands, contact support. The unit may need to be replaced.

Was This Article Helpful?