If an RM4014 does not acknowledge commands or call in as scheduled, please follow the steps below.
Steps
- Check the battery. Measure at the battery leads. It should read above 12.6 V. If it does not, replace it with a battery charged above 12.6 V, then check again.
- Check the DC power input. It should read 12 to 14 V DC. If it does not, check the power supply and its power source, then check again.
- Check the satellite terminal. It needs the right orientation and a clear line of sight to the sky. Fix anything that blocks it, then check again.
- Check the satellite cable. Make sure both ends are tight and the cable is not damaged. Replace a damaged cable, then check again.
- If the unit still does not call in or acknowledge commands, contact support. The unit may need to be replaced.