(AI KB) Bullhorn RM1250 and RM3250: Not Powering On or Not Communicating

Use these checks when a Bullhorn RM1250 or RM3250 shows no sign of life, will not connect, or has stopped reporting to Bullhorn Web.

Applies to: Bullhorn RM1250 and RM3250.

Steps:

  1. Wake the unit. Swipe a magnet across the access point, marked with an arrow on the dome. A red light flashes while the unit waits to pair.
  2. No red light? Check the batteries. Loosen the two screws that hold the dome and lift it carefully, so the wiring stays connected. The larger, round battery plugs into P4. The bundled pair of batteries plugs into P3. Unplug both, then plug them back in. The unit clicks when it powers on.
  3. Still no click or red light? Replace the batteries. Use battery set part number 517206-000. It has one 3.6 V battery and one 7.2 V rechargeable pair.
  1. Connect with Bullhorn Tools. Turn on Bluetooth on your phone or tablet or connect directly with the mini-USB. Open Bullhorn Tools and select the unit from the list. The unit's name includes the serial number from the Bullhorn sticker on the dome.
  2. Check power in the app. Open the menu and tap the Unit for Unit Overview. You can confirm the Battery status and DC Input voltage.
  3. Send a test message. Tap Action and then Send Test Message, then tap Yes. Wait for the confirmation status.
  4. Check Bullhorn Web. Open the unit's Unit Detail page and click the Incoming Packets tab. Look for a packet labeled Test.
  5. Check the schedule. In Bullhorn Tools, open the menu and tap Reporting & Power. Confirm an interval and a Start Time are set, then tap Save. On an RM3250, a blank interval means no scheduled transmission.
  6. Check the signal. Both units use a cellular network. The Radio SNR reading on the Unit Overview should be at least 40 dB for a stable link.

Good to know:

  • When the batteries are connected, the unit sends a Startup packet to Bullhorn Web.
  • Settings changed in Bullhorn Web are queued. A test message makes the unit call in, and the queued settings are then applied.
  • Bluetooth turns off by itself after 10 minutes. Swipe the magnet again to reconnect.
  • If the data log fills up, the unit may report between its scheduled times.
  • The battery is the only part of an RM3250 that can be serviced in the field.
  • Older RM1250 units were built for a cellular network that has shut down. They need an LTE retrofit to communicate. Contact support to arrange one.

When to contact support:

Submit a support case if any of these is true:

  • There is no click and no red light with a new battery set.
  • The test message fails after several tries.
  • The Radio SNR reading is below 37 dB.
  • The unit is missing from your Bullhorn Web account.

Was This Article Helpful?

0 out of 0 found this helpful