(AI KB) Bullhorn RM520 and RM540: Will Not Interrupt or No Instant Off Reading

Use these checks when an RM520 does not interrupt, or an RM540 does not return an instant off reading.

Applies to: RM520C, RM520S, RM540C, RM540S
 

RM540 Units are Interruption Aware, they can be set to interrupt to obtain Instant ON/OFF readings but do not physically have a relay associated to interrupt. 

Steps:

  1. In Bullhorn Web, check the outgoing packets for the unit. Confirm that your interruption command was sent to the unit.
  2. Check that the unit has a GPS lock either on Bullhorn Web or using Bullhorn FieldPro.
  3. Check the battery voltage. A low battery at 6V or less can stop the unit from interrupting.
  4. Check the relay wiring:
    • Blue goes to Relay control (+) 
    • Blue/White goes to Relay control (-)
  5. Check the schedule that was sent to the unit through Bullhorn Web or Bullhorn FieldPro
    • For Instant Off: Ensure that it is enabled on the Interruption settings on the appropriate channel, if it is not enabled, it will not provide the instant off value despite interruption.

Good to know:

  • The RM520 and RM540 run on AA lithium batteries at 1.5 VDC each. 
    • The RM520 and the RM540 each use 8. One dead battery is enough to cause problems.

Please follow your company's safety checklist when you work on this equipment.

When to contact support:

If the unit still does not interrupt after these checks, submit a support request. Include the unit serial number and the schedule shown in FieldPro.