(AI KB) Bullhorn RM510C and RM510S: Will Not Cycle or Interrupt

Use these checks when an RM510C or RM510S does not interrupt the rectifier, or the relay seems stuck.

Applies to: RM510C, RM510S

Steps:

  1. Measure the Red/Red-white wires going to the RM5 I/O 4 module from the terminal block. It should read 12 to 14 VDC. Ensure the correct polarity with the opposite side of the block. If there is no power here, the unit treats the rectifier as being in AC fail and will not interrupt.
  2. Check that the unit has a GPS lock either on Bullhorn Web or using Bullhorn FieldPro.
  3. Check that the relay is wired to the rectifier correctly - Bus Bar removed on the portion that is being interrupted and interruption cables not overlapping any power supply.
  4. Relay Troubleshooting:
    1. If using an REL2510:
      • Check that it has 7 to 30 VAC or VDC on Ext Power.
      • Check that the rectifier output is within the relay's limits: 100 volts and 100 amps maximum (70 RMS).
    2. If using a Mercury relay:
      • Check that it is mounted upright and that the full cycle is 5 seconds or longer.
    3. If using a AC Crydom relay:
      • Check for at least 24 volts on the taps that are being interrupted.
    4. If using a DC Crydom relay:
      • Check the polarity of the welding cables and that V Power has 8 to 20 VAC or 7 to 30 VDC.

Good to know:

  • DC Crydom relay:
    • On the positive side: the relay's positive cable goes to the DC positive lug on the rectifier. The negative cable goes to the positive anode cable.
    • On the negative side: the relay's negative cable goes to the DC negative lug on the rectifier. The positive cable goes to the negative structure cable.

Please follow your company's safety checklist when you work on this equipment.

When to contact support:

If the unit still does not interrupt after these checks, submit a support request. Include the unit serial number, the relay model, and the DC input voltage you measured.