Use this article to send a Read on Demand or Stop Interruption, to see if a command reached the unit, or to cancel a command or a scheduled interruption.
Steps (Read on Demand & Stop Interruption):
- Hover over Units and select All Units.
- Select Commands
- While the Commands pane is open
- Choose Read on Demand or Stop Interruption.
- Select the unit or units.
Read on Demand returns the analog readings and a health check.
Stop Interruption stops any interruption program that is running.
Steps (Command Verification):
- Hover over Units and select Send Commands.
- Click refresh to load the latest information.
- On the Schedule tab, read the Status and Completion columns for your command.
- For older commands, open the History tab. You can filter by unit, unit type, status or date.
Steps (Cancel Commands):
This is only available for RM4 Series Units, Contact Support for RM5 Series or wait for the unit to reattempt (It will attempt up to 5 times)
- Select the unit you want to cancel a command for
- Click the Outgoing Packets tab
- To cancel, click the X on the right side of the command. (This option is not available for RM5 Units)
Steps (Cancel or Adjust Interruption):
- Select the unit you want to cancel or change interruption
- Click the Outgoing Packets tab
- To cancel, click the X on the right side of the command. (This option is not available for RM5 Units)
- To change the Interruption after cancelled:
- Return to the All Units page and select Interruption
- Change the interruption mode
- Change the Start/Stop Date and Time (Ensure Time Zone is correct)
- Change the ON/OFF Cycle and Synchronize (Starting in OFF or ON)
- Check the Units you're wanting to interrupt on the main panel
- Click Send on the Interruption Panel
- Select the unit and Settings on the Unit Detail pane
- Click the (+) to for RM5 Series and select Interruption
- Change the Interruption Mode
- Ensure Time Zone is correct
- Set Synchronize Settings (Starting in OFF or ON)
- Change the Start/Stop Date and Time
- Change the ON/OFF Cycle Times
- Click Save
- Settings for RM4 Series
- Ensure Time Zone is correct
- Set Synchronize Settings (Starting in OFF or ON)
- Change the Interruption Mode
- Change the Start/Stop Date and Time
- Change the ON/OFF Cycle Times
- Click Save
- Select Send Settings on the Left Side
- Click Sync Unit Settings
- Click the (+) to for RM5 Series and select Interruption
- Return to the All Units page and select Interruption
Good to know:
- When a unit does not acknowledge a command or settings, Bullhorn Web emails the person who sent it. The email has a link to Resend, or to Revert settings to the last ones that worked.
- A command may not be received because of network issues, unit configuration problems, or because the unit is turned off.
- Commands to RM4150 and RM4151 units are sent immediately and cannot be canceled.
- To see which units are interrupting, open All Units and tick an interruption status in the Status Filter pane, for example Cathodic Protection Off, then click Apply.
When to contact support:
- A command still fails after a resend and the unit is reporting normally.
- A command is preventing additional communication on an RM5 Series Unit
- A unit keeps showing an interruption or Cathodic Protection Off status after you sent Stop Interruption and the unit has reported in again.