Use this article to replace the batteries in a Bullhorn RM520 or RM540, and to see how long the batteries last.
Applies to: Bullhorn RM520C, RM520S, RM540C and RM540S.
Steps
- Remove the test station cap. Remove the Phillips screw that holds the unit on the test head mounting plate. Lift the unit off. Keep the screw.
- Unplug the wiring cable connector from the bottom of the unit.
- Loosen the screws in the top cap until they spin freely. Pull the cap straight off the unit. The screws stay in the cap.
- Hold the circuit board by its tabs and tip the old batteries out.
- Put in the new batteries. Follow the polarity marked on the circuit board.
- Put the cap back on. Press it down against the springs and line up the gold pins with the pads.
- Hold the cap down and tighten the screws. The blue Wake/Config light should come on while you tighten.
- Reconnect the wiring cable connector.
- Put the unit back on the test head mounting plate and fit the screw.
- Connect with the Bullhorn FieldPro app and send a test message. Then put the test station cap back on.
Good to know
- Battery life: about 5 years for the RM520 and about 10 years for the RM540. It depends on the operating conditions and on how often the unit reports.
- The RM520 uses more power than the RM540, because it runs GPS sync and bond interruption.
- Battery type: AA lithium, 1.5 V each, non-rechargeable. American Innovations recommends Lithium L91 AA batteries.
- The RM520 uses eight AA batteries. The RM540 uses four.
- The batteries can be replaced in the field.
- One dead battery is enough to cause problems.
- You do not need to take the circuit boards out to change the batteries. If the boards slide out, plug the battery holder board onto the main board, slide the main board back into the case and line up its pins with the holes in the case. Some RM540 units have boards that are glued in place.
- Do not touch the bare contacts or parts on the circuit board while the cap is off.
- To order batteries, email sales@aiworldwide.com.
Please follow your company's safety checklist when you work on this equipment.
When to contact support
- The blue Wake/Config light does not come on when the cap is screwed down.
- The unit does not send a test message with new batteries.
- The batteries run down much sooner than expected.