Use this article to set up interruption on a Bullhorn RM4010, RM4011, RM4014 or RM4015 from a PC with Bullhorn Tools, and to check that the unit interrupts.
Applies to: Bullhorn RM4010, RM4011, RM4014, RM4014S and RM4015.
Steps
- Connect the configuration cable to a USB port on your PC and to the USB CONFIG port on the front of the unit.
- Open Bullhorn Tools on the PC. Select the unit and click Connect. The Unit Overview window opens. Click Refresh.
- Click Interruption. The Interruption window opens.
- Choose the Interrupter Mode: Off, Daily, Start/Stop or Continuous. For Daily, enter a Start Time and a Stop Time. For Start/Stop, enter a Start Date, a Stop Date, a Start Time and a Stop Time.
- Type the On Time and the Off Time, in seconds.
- Choose the Output Mode that matches your relay: Normally Closed or Normally Open.
- Choose the Sync Mode. Off/On starts with the off cycle. On/Off starts with the on cycle.
- Click Save.
- Click Verify Interruption, then click Verify. The check takes about a minute.
- Wait for the message "Interruption Verification Passed". Click OK.
- If you see "Interruption Verification Failed", look at the GPS Information pane. Number of Satellites must be 3 or more. If it is lower, move the GPS antenna to a spot that is clear of obstacles.
- Check that incoming power is on. The check cannot pass while the unit runs on its battery only. Then verify again.
Good to know
- On Time and Off Time can be set in steps of 0.1 second. The shortest full cycle is 0.2 seconds.
- With a mercury relay, keep the full cycle at 5 seconds or longer.
- You can also send interruption settings from Bullhorn Web. See the article "Bullhorn Web: How To Send Interruption Settings To Units". Bullhorn Web does not override interruption that was set from Bullhorn Tools.
- Interference mode is optional. In the Interruption window set Interference Mode to Enable, then enter the Number of Units, this unit's Unit Number and the Delay in seconds.
- When you finish, click File, then Exit. Disconnect the cable, then close and latch the enclosure door.
- You can download Bullhorn Tools for PC from support.aiworldwide.com, under Downloads.
- If Bullhorn Tools will not connect on your PC, see the article "Bullhorn Tools: PC Connection Troubleshooting".
Please follow your company's safety checklist when you work on this equipment.
When to contact support
- Interruption verification fails a second time.
- Verification passes but the rectifier does not switch. First see the article "Bullhorn RM4014 and RM4015: Wrong Readings or Will Not Interrupt".