(AI KB) Bullhorn RM4010, RM4011, RM4014 and RM4015: Set Up and Verify Interruption with Bullhorn Tools on a PC

Use this article to set up interruption on a Bullhorn RM4010, RM4011, RM4014 or RM4015 from a PC with Bullhorn Tools, and to check that the unit interrupts.

Applies to: Bullhorn RM4010, RM4011, RM4014, RM4014S and RM4015.

Steps

  1. Connect the configuration cable to a USB port on your PC and to the USB CONFIG port on the front of the unit.
  2. Open Bullhorn Tools on the PC. Select the unit and click Connect. The Unit Overview window opens. Click Refresh.
  3. Click Interruption. The Interruption window opens.
  4. Choose the Interrupter Mode: Off, Daily, Start/Stop or Continuous. For Daily, enter a Start Time and a Stop Time. For Start/Stop, enter a Start Date, a Stop Date, a Start Time and a Stop Time.
  5. Type the On Time and the Off Time, in seconds.
  6. Choose the Output Mode that matches your relay: Normally Closed or Normally Open.
  7. Choose the Sync Mode. Off/On starts with the off cycle. On/Off starts with the on cycle.
  8. Click Save.
  9. Click Verify Interruption, then click Verify. The check takes about a minute.
  10. Wait for the message "Interruption Verification Passed". Click OK.
  11. If you see "Interruption Verification Failed", look at the GPS Information pane. Number of Satellites must be 3 or more. If it is lower, move the GPS antenna to a spot that is clear of obstacles.
  12. Check that incoming power is on. The check cannot pass while the unit runs on its battery only. Then verify again.

Good to know

  • On Time and Off Time can be set in steps of 0.1 second. The shortest full cycle is 0.2 seconds.
  • With a mercury relay, keep the full cycle at 5 seconds or longer.
  • You can also send interruption settings from Bullhorn Web. See the article "Bullhorn Web: How To Send Interruption Settings To Units". Bullhorn Web does not override interruption that was set from Bullhorn Tools.
  • Interference mode is optional. In the Interruption window set Interference Mode to Enable, then enter the Number of Units, this unit's Unit Number and the Delay in seconds.
  • When you finish, click File, then Exit. Disconnect the cable, then close and latch the enclosure door.
  • You can download Bullhorn Tools for PC from support.aiworldwide.com, under Downloads.
  • If Bullhorn Tools will not connect on your PC, see the article "Bullhorn Tools: PC Connection Troubleshooting".

Please follow your company's safety checklist when you work on this equipment.

When to contact support

  • Interruption verification fails a second time.
  • Verification passes but the rectifier does not switch. First see the article "Bullhorn RM4014 and RM4015: Wrong Readings or Will Not Interrupt".

Was This Article Helpful?

0 out of 0 found this helpful