(AI KB) Bullhorn RM4210, RM4211, RM4250 and RM4251: Battery Life and Battery Replacement

Use this article to see how long the batteries last in a Bullhorn RM4210, RM4211, RM4250 or RM4251, and to replace them.

Applies to: Bullhorn RM4210, RM4211, RM4250 and RM4251.

Steps

  1. Loosen the two screws that hold the dome on the test station adapter or flat base adapter.
  2. Lift the dome carefully, so the wiring stays connected.
  3. Unplug both batteries from their connections on the faceplate.
  4. Unfasten the Velcro strap on the battery bracket and take the batteries out.
  5. Put the new batteries in the bracket. The bundled pair slides in under the bracket. The larger, round battery sits next to it. Fasten the strap.
  6. Plug the larger, round battery into P4.
  7. Plug the bundled pair of rechargeable batteries into P3. The unit clicks when it powers on. That is normal.
  8. Set the unit back on the adapter, with the wiring wrapped inside the dome. Tighten the screws.
  9. Connect with the Bullhorn Tools Mobile app and send a test message.

Battery life

The batteries usually last 3 to 7 years. It depends on the operating conditions and on how often the unit measures and reports. A battery set that lasts only six months is not normal.

These are the estimates from American Innovations for each schedule, in years.

Measures everyReports dailyReports weeklyReports monthly
Quarter hour1.11.21.2
Hour2.63.43.6
Day4.78.910
Week4.99.410.7

Good to know

  • The battery set is part number 517206-000. It has one 3.6 V battery and one 7.2 V rechargeable pair. On the store it is listed as "RM42XX Replacement Batteries".
  • A battery set that runs down in a few months is not normal. Check the measurement and reporting schedule first, then contact support.
  • On the RM4210 and RM4250, the battery is the only part you can service in the field.
  • Do not twist the dome if its cut-outs do not line up with the screws. Lift it off and set it down in the right position.
  • Battery status and DC Input voltage show at the top of the main unit screen in the Bullhorn Tools Mobile app.
  • To record the change, open the Reporting & Power screen in Bullhorn Tools Mobile, set the Battery Install Date and tap Update.
  • An optional power supply or solar panel can power the unit through the DC/Solar connector. See the article "Bullhorn Parts and Accessories You Can Order Online".
  • The RM42XX series moves from Bullhorn Tools to the Bullhorn FieldPro app in 2027. After that change, use FieldPro for these steps.

Please follow your company's safety checklist when you work on this equipment.

When to contact support

  • There is no click with a new battery set.
  • A battery set runs down much sooner than the table shows for your schedule.
  • The unit does not send a test message with new batteries. First see the article "Bullhorn RM4210, RM4211, RM4250 and RM4251: Not Powering On or Not Communicating".

Was This Article Helpful?

0 out of 0 found this helpful