Use these checks when a Bullhorn RM4210, RM4211, RM4250 or RM4251 shows no sign of life, will not connect, or has stopped reporting to Bullhorn Web.
Applies to: Bullhorn RM4210, RM4211, RM4250 and RM4251.
Steps:
- Wake the unit. Swipe a magnet across the access point, marked with an arrow on the dome. A red light flashes while the unit waits to pair.
- No red light? Check the batteries. Loosen the two screws that hold the dome and lift it carefully, so the wiring stays connected. The larger, round battery plugs into P4. The bundled pair of batteries plugs into P3. Unplug both, then plug them back in. The unit clicks when it powers on.
- Still no click or red light? Replace the batteries. Use battery set part number 517206-000. It has one 3.6 V battery and one 7.2 V rechargeable pair.
- Connect with Bullhorn Tools Mobile. Turn on Bluetooth on your phone or tablet. Open the Bullhorn Tools Mobile app. Units that are awake show on the screen. Swipe down to refresh if yours is missing. Tap the unit name, then tap OK.
- Check power in the app. Battery status and DC Input voltage show at the top of the main unit screen.
- Send a test message. In Bullhorn Tools Mobile, open Send Test Message and tap Send Test Message.
- Check Bullhorn Web. Open the unit's Unit Detail page and click the Incoming Packets tab. Look for a packet labeled Test.
- Check the schedule. In Bullhorn Tools Mobile, open the Reporting & Power screen. Confirm an Interval and a Start Time are set. Tap Update.
- Check for an over-current alarm. When the test coupon relay trips, some readings show as INVALID. Fix the cause of the over-current first. Then tap Reset Over-Current on the main unit screen in Bullhorn Tools Mobile.
- Check the location. The RM4210 and RM4211 use a satellite that sits directly south of North America. Keep the unit clear of anything that blocks its view of the sky. The RM4250 and RM4251 use a cellular network.
Good to know:
- When the batteries are connected, the unit sends a Startup packet to Bullhorn Web. A Startup packet has no readings. Readings arrive at the next scheduled time.
- Settings changed in Bullhorn Web are queued. A test message makes the unit call in, and the queued settings are then applied.
- Bluetooth turns off by itself after 10 minutes. Swipe the magnet again to reconnect.
- The Radio SNR reading should be at least 40 dB for a stable connection.
- The RM42XX series moves from Bullhorn Tools to the Bullhorn FieldPro app in 2027. After that change, use FieldPro for these steps.
- After an over-current, the unit tries to reset the relay by itself after 1 minute. If it trips again within 10 minutes, the relay stays open until you reset it.
- You can also reset an over-current from Bullhorn Web. See the article "How To Reset Over-Current Alarm For RM42XX Units".
- If the unit is missing from your Bullhorn Web account, see the article "Cannot Find Bullhorn RMU Unit On Bullhorn Web".
When to contact support:
Submit a support case if any of these is true:
- There is no click and no red light with a new battery set.
- The test message fails after several tries.
- The Radio SNR reading is below 37 dB.
- The over-current alarm comes back after you fixed the cause and reset it.
- The unit is in another company's account, or it was decommissioned.
To send support the details, please provide a screenshot of your Bullhorn Tools screen. You can also open the unit information screen in Bullhorn Tools Mobile and tap Email Support. The email includes a log of the session.