Use these checks when an older Bullhorn RM4011, RM4015, RM4016 or RM4020 will not power on or has stopped reporting to Bullhorn Web.
Applies to: Bullhorn RM4011, RM4015, RM4016 and RM4020.
Steps:
- Check the power switch. Open the enclosure and make sure the unit's power switch is ON. The unit makes a clicking sound when it is on.
- Check the DC input. Measure the voltage at the unit's DC Input connector. With an AC or DC power supply it should read about 12 V DC. If it does not, check the power supply or charger and its power source.
- Check the battery. Disconnect the charger or solar panel, then measure at the battery leads. The battery should read above 12.6 V. Recharge it at 12.5 V or less. Replace it at 12 V or less.
- Check the fuse. On an RM4011, RM4015 or RM4016, turn the power switch OFF, then pull the fuse. Replace a blown fuse with a 3 amp Cooper Bussmann ATC-3 fuse.
- Restart the unit. Flip the power switch located by the fuse on the top of the unit.
- Check the satellite terminal or antenna. It needs a clear view of the sky to the south, with no buildings, trees or hills in the way. The serial number on the antenna needs to match the MIN on Bullhorn Web, it will contain 'SKY' in the serial. If the rectifier has a solar panel, ensure that the antenna is 2 feet above the panel itself.
- Check the cables. Make sure every connector is tight. Inside the enclosure, keep the antenna cable away from the radio and the battery. If the signal keeps dropping, replace the cable between the satellite terminal and the unit.
- Send a test message. Connect a PC to the Mini-USB CONFIG port on the unit and open Bullhorn Tools. Check the satellite signal strength, then send a test message. The RM4020 uses the UCT software for this (This can be downloaded here).
- Check Bullhorn Web. For an RM4011 or RM4015 check unit details, and confirm new readings or status close to the time of the fix being applied or requested.
Good to know:
- The RM4016 and RM4020 are one-way units. They report only on their schedule, and commands cannot be sent to them. After a fix, wait for the next scheduled report or send a test message.
- On an RM4020, the RADIO light on the faceplate is red while the unit looks for the satellite. It turns green when the unit is connected.
- The older satellite network for the RM4011 ended in December 2021. An RM4011 with the IDP satellite terminal upgrade shows as an RM4015 in Bullhorn Web. An RM4011 without the upgrade cannot communicate.
- Low battery warnings in Bullhorn Web mean the battery and its charger should be checked soon.
- The RM4016 charges its battery from a solar panel.
- The RM4011 and RM4015 use a Power Sonic PS-1221S battery, 12 V, 2.0 AH. The AI part number is 370149-000.
- If Bullhorn Tools will not connect on your PC, see the article "Bullhorn Tools: PC Connection Troubleshooting".
When to contact support:
Submit a support case if any of these is true:
- Every check above passes and the unit still does not acknowledge commands.
- Any test message fails after several tries.
- A new battery is installed and will not hold a charge.
Have ready: The serial number, the DC input voltage, the battery voltage, and what Bullhorn Tools shows when you send a test message.